Products
- Vacuum Cavitation System[7]
- IPL Machine[10]
- RF Equipment[7]
- PDT Machine[3]
- Skin Scrubber[7]
- Derma Rolling System[7]
- Laser Beauty Equipment[10]
- Oxygen Jet[7]
- No-Needle Mesotherapy Device[7]
- Microdermabrasion Machine[7]
- Skin Analyzer[2]
- Other Beauty & Personal Care Products[3]
- Multi-Functional Beauty Equipment[2]
- Face & Body Mask[7]
- UV Lamp[7]
- Teeth Whitening[6]
- Dental Equipments[3]
- Emergency & Clinics Apparatus[5]
- General Assay & Diagnostic Apparatus[10]
- Other Shoes[1]
Contact Us
- Contact Person : Ms. Xie Candy
- Company Name : Beijing Huateng Zhongxun Tech Co., Ltd.
- Tel : 86-010-82958683
- Fax : 86-10-82958683
- Address : Beijing,Beijing,Room 627, 6th Floor, Tongyuan Building, No. 95, Qinghe St. 3, Haidian District
- Country/Region : China
15 Inch Screen Color TFT Display Multi-parameter Patient Monitor
Product Detailed
Related Categories:Emergency & Clinics Apparatus
Patient Monitor Medical Equipment
CE approved
Fast delivery
Best quality and service
1 year guarantee
15 inch screen Color TFT Display Multi-parameter Patient Monitor with CE Approved
Discription:
Item No. | patient monitor004 | |||
Display Size: | 15'' | |||
Description: | 370*160*333mm | |||
ECG: | 1.lead mode:I II III,AVR.VL.AVF.V | |||
2.GAIN:*0.25.*0.5.*1.*2 | ||||
3.hear rate:15-300 bpm(adult) | ||||
15-350bpm(pediatric) | ||||
resolution:1bpm | ||||
accuracy:+-1% | ||||
4.bandwidth:diagnostic:0.05-130Hz | ||||
Monitor:0.5-40Hz | ||||
Surgery:1-20Hz | ||||
5.Sweep speed:12.5mms,25mm/s | ||||
,50mm/s | ||||
6.pacemaker rejection:Yes | ||||
7.ST measurement Range:-2.0+-2.0mv | ||||
accuracy:+-0.02mv or +-10% which is | ||||
greater | ||||
Spo2 | 1.measure range:0-100% | |||
2.resolution:1% | ||||
3.accuracy:+-2% | ||||
4.pulse rate:20-300bpm | ||||
resolution:1bpm | ||||
accuracy:+-3bpm | ||||
NIBP | 1.work mode: manual,automatic, | |||
continuous | ||||
2.Unit: mmHg,Kpa | ||||
3.Measure range: | ||||
adult: SYS:40-280mmhg | ||||
DIA:10-220mmhg | ||||
MEAN:20-240mmhg | ||||
Pediatric:SYS:40-220mmhg | ||||
DIA:10-160mmhg | ||||
MEAN:20-170mmhg | ||||
neonatal:SYS:40-135mmhg | ||||
DIA:10-100mmhg | ||||
MEAN:20-100mmhg | ||||
4.Resolution:1mmhg | ||||
5.Accuracy:max mean error:+-5mmhg | ||||
max standard deviation:8mmhg | ||||
6.Overpressure protection: | ||||
Adult:300mmhg | ||||
Pediatric | 240mmhg | |||
Neonatal | 150mmhg | |||
7.Degree of protection:BF.CF | ||||
RESP | 1.Measure range: Adult:0-120rpm | |||
pediatric.neonatal 0-150rpm | ||||
2.Resolution:1 rpm | ||||
3.Accuracy:+-2% | ||||
TEMP | 1.channels:2 | |||
2.measure range:0-50°c | ||||
3.resolution:0.1°c | ||||
4.Accuracy:+-0.1°c(25-45c°) | ||||
IPM(optional) | ||||
1.channels:2 | ||||
2.measure range:-50-360mmhg | ||||
3.accuracy:+-2%or +-1mmhg which is | ||||
greater | ||||
Co2(optional) | ||||
1.measure range:0%-13% | ||||
2.Resolution:1mmhg | ||||
3.accuracy:+-12mmhg@<5.0%co2 | ||||
at ATPS | ||||
4.Resp:3-15rpm | ||||
Ioc(optional) | ||||
EEG sensitivity:+-475V | ||||
CMRR:>100DB | ||||
Input impedance >50Mohm | ||||
IoC 0-100 | ||||
ESR 0-100% | ||||
EMG:0-100 | ||||
Recorder optinal | ||||
1.Width:48mm | ||||
2.speed:25-50mm | ||||
3.channels:2 |