- Vacuum Cavitation System[7]
- IPL Machine[10]
- RF Equipment[7]
- PDT Machine[3]
- Skin Scrubber[7]
- Derma Rolling System[7]
- Laser Beauty Equipment[10]
- Oxygen Jet[7]
- No-Needle Mesotherapy Device[7]
- Microdermabrasion Machine[7]
- Skin Analyzer[2]
- Other Beauty & Personal Care Products[3]
- Multi-Functional Beauty Equipment[2]
- Face & Body Mask[7]
- UV Lamp[7]
- Teeth Whitening[6]
- Dental Equipments[3]
- Emergency & Clinics Apparatus[5]
- General Assay & Diagnostic Apparatus[10]
- Other Shoes[1]
- Contact Person : Ms. Xie Candy
- Company Name : Beijing Huateng Zhongxun Tech Co., Ltd.
- Tel : 86-010-82958683
- Fax : 86-10-82958683
- Address : Beijing,Beijing,Room 627, 6th Floor, Tongyuan Building, No. 95, Qinghe St. 3, Haidian District
- Country/Region : China
multi-parameter patient monitor
1. Feature:1.Color TFT display, support 12 channel waves, 6 parameters include: ECG/RESP, NIBP, SpO2, TEMP, dual IBP, CO2, IoC.2. Unique human voice alarm.3. Rich screen layouts: Standard, big font, trend table, NIBP trend, ECG full lead, OxyCRG, IOC Layout.4. Powerful storage: maximum 720 hour graphic and tabular trends of all parameters, up to 10000 NIBP review, 200 alarm event review, 2 hours of all waveforms.5. System software can be upgraded through network.6. Standard configuration: ECG, RESP, TEMP, NIBP, SpO27. Optional: dual IBP, CO2, IoC, Recorder, VGA.
2. Specification:
Item No. | KD patient monitor002 | ||
Screen Size: | 10 inch | ||
ECG | Lead mode:I II III,AVR.VL.AVF.V | ||
GAIN:*0.25.*0.5.*1.*2(mm/mV) | |||
Hear rate: | 15-300 bpm(adult) | ||
15-350bpm(pediatric) | |||
Resolution:1bpm | |||
Accuracy:+-1% | |||
Bandwidth: Diagnostic:0.05-130Hz | |||
Monitor:0.5-40Hz | |||
Surgery:1-20Hz | |||
Sweep speed:12.5mms,25mm/s,50mm/s | |||
Pacemaker rejection:Yes | |||
ST measurement Range:-2.0+-2.0mv | |||
Accuracy:+-0.02mv or +-10% which is greater | |||
Spo2 | Measure range:0-100% | ||
Resolution:1% | |||
Accuracy:+-2% | |||
Resolution:1bpm | |||
Accuracy:+-3bpm | |||
NIBP | Work mode: manual,automatic,continuous | ||
Unit: mmHg,Kpa | |||
Measure range: | adult: SYS:40-280mmhg | ||
DIA:10-220mmhg | |||
MEAN:20-240mmhg | |||
Pediatric:SYS:40-220mmhg | |||
DIA:10-160mmhg | |||
MEAN:20-170mmhg | |||
Neonatal:SYS:40-135mmhg | |||
DIA:10-100mmhg | |||
MEAN:20-100mmhg | |||
Resolution:1mmhg | |||
Accuracy: max mean error:+-5mmhg; max standard deviation:8mmhg | |||
Overpressure protection:0-300mmhg | |||
Degree of protection:BF.CF | |||
RESP | Measure range: | Adult:0-120rpm | |
pediatric.neonatal 0-150rpm | |||
Resolution:1 rpm | |||
Accuracy:+-2% | |||
TEMP | Channels:2 | ||
Measure range:0-50°c | |||
Resolution:0.1°c | |||
Accuracy:+-0.1°c(25-45c°) | |||
IPM (optional) | Channels:2 | ||
Measure range:-50-360mmhg | |||
ccuracy:+-2%or +-1mmhg which is greater | |||
Co2 (optional) | Measure range:0%-13% | ||
Resolution:1mmhg | |||
Accuracy:+-12mmhg@<5.0%co2 (at ATPS) | |||
Resp:3-15rpm | |||
Ioc(optional) | EEG sensitivity:+-475uV | ||
CMRR:>100DB | |||
Input impedance: >50Mohm | |||
IoC: 0-100 | |||
ESR: 0-100% | |||
EMG: 0-100 | |||
Recorder optinal | Width:48mm | ||
Speed:25-50mm | |||
Channels:2 |
multi-parameter patient monitor